Hiding a router and its cables in a small office room

Hiding a router and its cables in a small office room
Photograph: Slick · CC0 · Wikimedia Commons

Putting the router in the room you work in is a cable problem first and a signal problem second. Most people solve it in the wrong order.

Why the router ended up in the office

Ellis took the ground-floor flat knowing the fibre entered at the skirting board of the small back room. The provider would not move the entry point without a fee and a date.

So the router sat in the room he also worked in, on a shelf above the desk. Every cable in the flat passed through his eyeline.

The arrangement worked for the connection and failed for the room. Heat, cable clutter and a blue status light arrived in the room together.

The heat problem nobody plans for

A router runs continuously and dissipates five to fifteen watts from a plastic box with no fan. That heat leaves through slots on the top and sides.

Ellis first put his in a closed cabinet with the printer. The cabinet reached 38 degrees and the connection dropped twice a week.

Electronics do not fail immediately at that temperature. They fail slowly over months, which is why the mistake is so easy to keep making.

The five centimetre rule

A router needs about five centimetres of clear air on every vented face and never on carpet or paper. That is the whole of the cooling requirement.

Ellis’s first shelf had 2 cm above the unit and a stack of notebooks against one side. Moving the notebooks was the entire fix.

Open air on all sides is worth more than a fan. Fans add noise and dust and only matter when the clearance cannot be given.

Running the cable along the skirting

The fibre drop entered at 12 cm above the floor, which meant the cable had to travel 2 m to reach the shelf. Ellis did not want a diagonal across the wall.

He ran it horizontally along the top of the skirting and up the corner behind a curtain. The run is 2.1 m and uses three adhesive clips.

A corner is the cheapest place to hide a vertical cable because nobody looks there. Straight lines read as wiring and corners read as architecture.

The shelf height that fixed the signal

A router radiates outward and slightly down, so a shelf at 1.4 m clears the desk and the chair back. Ellis had his at 2.1 m, near the ceiling.

At ceiling height the signal had to pass through the shelf and then descend to his laptop. Throughput on the far side of the flat fell by a third.

Dropping the unit 70 cm restored the far room and did not disturb the desk. Height is the only router setting that costs nothing to change.

What a cupboard does to a signal

A cupboard is a metal-free box only if the door is thin, and most doors are 18 mm of board over air. That is enough to take 3 to 6 dB out of the link.

Ellis tried a cupboard for two days and measured the loss with a phone app on the same spot. The far bedroom went from usable to intermittent.

Hiding a router inside furniture is the most common version of this mistake. Ventilation and radiation want the same thing, which is open air.

Metal, glass and the desk itself

A steel desk leg, a mirror and a fish tank all reflect or block the band a router uses. Ellis had a metal monitor stand directly in front of the unit.

He rotated the router 90 degrees so the stand no longer sat in the main lobe. The near-room signal improved without anything being moved.

Reflections matter more than distance in a small room. A metre of clear line beats three metres routed through a metal filing cabinet.

The power strip mistake

Six devices on one strip under a desk is normal and usually fine, but the strip itself becomes the mess. Ellis’s had a switch and a coiled surplus.

He fixed the strip to the underside of the desk with two screws and trimmed the cables to length. Nothing hangs and nothing loops.

Coiled cable is the part of cable management people skip. It is also the part that reads as untidiness from the doorway.

Dust and the vents

A router on a shelf at 1.4 m collects less floor dust than one at 20 cm, which is one argument for the higher position. Ellis still cleaned his quarterly.

He found a felt of dust on the top slots after four months and vacuumed it with a brush head. The unit ran cooler and the dropouts stopped.

Dust is the slow failure that nobody attributes to the right cause. A calendar reminder is more useful than a better router.

Hiding the cable without trapping it

A cable trunk on the wall hides the run and traps heat if it also covers a vent. Ellis used a 2 cm channel that stopped below the unit.

The channel is white on a white wall and reads as a picture rail from two metres. It cost less than the shelf it serves.

Trunking is not cheating. A wall with one straight line on it looks more deliberate than a bare wall with none at all.

The quarterly check

Once a quarter Ellis pulls the unit forward, checks the vents and re-seats the fibre connector. The whole job takes four minutes and has caught two problems.

The first was a connector that had worked loose when the shelf was dusted. The second was a cable clip that had failed behind the curtain.

Maintenance on a router is boring and it is the reason his connection has been stable. Nothing about the setup is clever.

When moving the entry point is cheaper

The provider quoted a fee to move the fibre to the hallway, which was more than the shelf and the trunking together. Ellis declined on cost.

Two years later he would pay it, because the router is still in the room he works in. The blue light still sits above his monitor at night.

The cheap fix has a recurring cost that the expensive one does not. That trade is the one to make deliberately rather than by default.

If the fibre enters the room you work in, would you rather hide the cable or pay to move the entry point?